Horsman-joint RTD temperature probes TM1204(1)
|
|
Applications:
Heat exchanger
units, Refrigeration and testing equipments.
|
|
Technical data
Protection tube: Stainless steel
304/316
Sensor element:
Pt100, Pt500, Pt1000 meets IEC 751
Tolerance : Class
B: △t=±(0.30
+ 0.005 |t| )℃(standard)
Class A: △t=±(0.15 + 0.002 |t| )℃
Transmitter: Integrated temperature transmitter 24VDC, 4~20mA, 2-wire
Transmitter errors: standard ±0.5% . ±0.2% is optional.
Response time:t0.9 approx. 10secs, in water 0.2
m/sec, diameter 6mm